Overview
A set of function blocks for commanding servo ON, homing, JOG and positioning of an IAI SCON position controller from a PLC
In this sample, the PLC and SCON are connected via EtherNet/IP
The SCON operating mode is set to "Full direct value mode" (32 bytes)

NOTE
This sample uses an SCON, but it should also work with other controllers such as the PCON
It should also work in other operating modes such as "Half direct value mode" by changing the structure
When connecting via EtherCAT, MOVE the values of the variables set in the I/O map into the structure
Function block list
- Enable operation (SconPower)
- Homing (SconHome)
- Jog operation (SconMoveJog)
- Move (SconMove)
Symbols
Enable operation (SconPower)

In-out
- AxisStatus
- Axis input
- AxisCmd
- Axis output
Output
- Status
- Ready to run
Homing (SconHome)

In-out
- AxisStatus
- Axis input
- AxisCmd
- Axis output
Jog operation (SconMoveJog)

In-out
- AxisStatus
- Axis input
- AxisCmd
- Axis output
Output
- PositiveEnable
- JOG+
- NegativeEnable
- JOG-
Move (SconMove)

In-out
- AxisStatus
- Axis input
- AxisCmd
- Axis output
Input
- position
- Target position
- PosBand
- Positioning width
- Speed
- Speed
- ZonePositive
- Zone boundary +
- ZoneNegative
- Zone boundary -
- Acceleration
- Acceleration
- Deceleration
- Deceleration
- CurrentLimit
- Pressing current limit
- CurrentThreshold
- Load current threshold
- PUSH
- Pressing specification
- DIR
- Pressing direction FALSE=positioning TRUE=pressing
Output
- PEND
- Positioning complete signal
- PSFL
- Pressing missed
Structures

EtherNet/IP tag data link settings